Neutral Nylon Transfer Membrane - MagnaNeutral™

GVS Life Sciences Neutral Nylon Transfer Membrane is a pure polymer impregnated by an inert polyester web. 

  • Southern transfers
  • Northern transfers
  • Protein binding
  • Microarrays
  • Macroarrays
  • Dot/Slot blots
  • Radiolabeled detection systems
  • Non-radiolabeled detection systems
  • Colony lifts
  • Plaque lifts
  • Library screening

This controlled microporous nylon membrane is cast on an inert, internal support web that gives it added dimensional strength and stability to prevent cracking, tearing, curling and breaking. This added strength and durability is essential in protocols that require aggressive handling, such as colony lifts and plaque lifts.

Features and Benefits

  • Supported: Has added strength and durability preventing distortion or contamination in multiple reprobings
  • High binding capacity: With a nucleic acid binding capacity of approximately 350 μg/cm2, Magna Nylon - Transfer Membrane can bind a wide range of fragment sizes, increasing the efficiency of transfers
  • Hydrophilic: Eliminates the need for wetting agents that can potentially interfere with biological processes
  • Lot-to-lot consistency: Quality checks ensure lot-to-lot consistency, both down and across the polyester web, for depenable results every time

In addition to the dimensional strength and durability of GVS Life Sciences Neutral Nylon Transfer Membrane, its retention of macromolecules can also be enhanced using UV cross-linking. This process can be used to maximize the signal retention of nucleic acids and preserve the integrity of DNA or RNA transfers.

The purity and consistency of GVS Life Sciences Neutral Nylon Transfer Membrane, coupled with its added durability and sensitivity, make it an ideal membrane for use in medical research, scientific studies or test confirmations where precise biological pattern replications, such as DNA and RNA transfers, are integral to the success of the procedure.


Product Characteristics

USP Class VI testing

Passed

Thickness

65 - 125 μm

Extractables

<0.2% (<0.0015 mg/cm2)

Nucleic Acid Binding

350 μg/cm2

Maximum Operating Temperature

356°F (180°C)

Sealing Compatibility

Ultrasonics, Heat, Radio Frequency and Insert Molding

Pore Size Range

0.22 to 0.45 μm


PRODUCT CODE DESCRIPTION
1213373 Transfer membrane disk diam.132 mm, NY66 neutral 0.45 µm (50 pcs)
1213375 Transfer membrane disk diam.137 mm, NY66 neutral 0.45 µm (50 pcs)
1214428 Transfer membrane disk diam.82 mm, NY66 neutral 0.45 µm (100 pcs)
1213370 Transfer membrane disk diam.82 mm, NY66 neutral 0.45 µm (50 pcs)
1213410 Transfer membrane disk diam.85 mm, NY66 neutral 0.22 µm (50 pcs)
1213372 Transfer membrane disk diam.85 mm, NY66 neutral 0.45 µm (50 pcs)
1213403 Transfer membrane roll 200x3000 mm, NY66 neutral 0.45 µm (1 pc)
1213405 Transfer membrane roll 300x3000 mm, NY66 neutral 0.22 µm (1 pc)
1213364 Transfer membrane roll 300x3000 mm, NY66 neutral 0.45 µm (1 pc)
1213379 Transfer membrane sheet 150x150 mm, NY66 neutral 0.45 µm (5 pcs)
1213419 Transfer membrane sheet 200x200 mm, NY66 neutral 0.22 µm (5 pcs)
1213380 Transfer membrane sheet 200x200 mm, NY66 neutral 0.45 µm (5 pcs)
1213382 Transfer membrane sheet 220x220 mm, NY66 neutral 0.45 µm (5 pcs)